eISSN 2097-6046
ISSN 2096-7446
CN 10-1655/R
Responsible Institution:China Association for Science and Technology
Sponsor:Chinese Nursing Association

Chinese Journal of Emergency and Critical Care Nursing ›› 2026, Vol. 7 ›› Issue (11): 1307-1312.doi: 10.3761/j.issn.2096-7446.2026.11.004

• Special Planning—Nursing Care of Cardiopulmonary Resuscitation • Previous Articles     Next Articles

Application value and prognosis evaluation of end tidal carbon dioxide partial pressure monitoring in patients with cardiac arrest

CHEN Peng(), RONG Juan, WU Yun, XUAN Jiaojiao, WU Yao*()   

  1. Emergency Medicine Department, Lu’an Hospital Affiliated to Anhui Medical University,Lu’an, Anhui Province 237000, China.
  • Received:2026-01-07 Online:2026-11-10 Published:2026-11-06
  • Contact: *WU Yao,E-mail:25222633@qq.com

Abstract:

Objective To explore the application value of end tidal carbon dioxide partial pressure(PetCO2) monitoring in the quality and prognosis evaluation of cardiopulmonary resuscitation in patients with cardiac arrest in the emergency department,and to provide reference for clinical nurses to ensure high-quality cardiopulmonary resuscitation. Methods 172 patients with cardiac arrest admitted to the emergency department of a hospital from November 2023 to November 2025 were selected as the research objects. According to resuscitation outcomes,they were divided into the restoration of spontaneous circulation(ROSC) group(n=62) and the non-ROSC group(n=110). The general data and PetCO2 values at each time point were compared between the two groups. Some patients in ROSC group were further divided into a 7-day survival group(n=18) and death group(n=28) according to their survival status,and the predictive value of PetCO2 value at each time point for prognosis was analyzed. Receiver operating characteristic(ROC) curve was used to analyze the best cut-off value of PetCO2 in predicting ROSC and survival rate. Results There was a statistically significant difference in the location of onset between the ROSC group and non-ROSC group(P<0.05). The PetCO2 value of the ROSC group at each time point of CPR was significantly higher than that of non-ROSC group(P<0.001). There was a significant interaction between PetCO2 value and ROSC outcome and 7-day survival outcome at different time points(P<0.05). At 20 min of resuscitation,when the maximum value of Youden index was 0.830,the best cut-off value of ROSC was 14.5 mmHg(1 mmHg=0.133 kPa),and the area under the ROC curve was the largest(AUC=0.980,95%CI:0.958-1.000). The sensitivity and specificity were 90.3% and 92.7%,respectively. At 30 min of resuscitation,when the maximum value of Youden index was 0.889,the best cut-off value of 7-day survival rate was 32 mmHg,and the area under the ROC curve was the largest(AUC=0.992,95%CI:0.967-1.000). The sensitivity and specificity were 88.9% and 100%,respectively. Conclusion PetCO2 monitoring can dynamically and noninvasively evaluate the quality of cardiopulmonary resuscitation,and has important clinical value in predicting patients’ ROSC and short-term survival rate. Its continuous monitoring and wider application during cardiopulmonary resuscitation are recommended

Key words: Cardiac Arrest, End Tidal Carbon Dioxide Partial Pressure, Cardiopulmonary Resuscitation, Autonomous Circulation Recovery, Prognosis Evaluation