Nursing cooperation in PICC catheterization for patients with bilateral internal jugular vein thrombosis using magnetic navigation combined with intracardiac electrocardiogram technology

  • XU Zhe ,
  • YU Chao ,
  • WU Xiaoli
Expand
  • 1 Vascular Access Nurse Specialist Clinic, the First Affiliated Hospital Zhejiang University School of Medicine, Hangzhou 310003
    2 Intensive Care Unit, the First Affiliated Hospital Zhejiang University School of Medicine, Hangzhou 310003

Received date: 2025-11-30

  Online published: 2026-08-31

Supported by

Zhejiang Provincial Medical and Health Science and Technology Program Project(2022KY771)

Abstract

For a patient with bilateral internal jugular vein thrombosis,magnetic navigation combined with intracavitary electrocardiography technology was used for real-time positioning,coupled with posture and respiratory management,as well as dynamic catheter adjustment,to precisely control the catheter trajectory. Additionally,a modified calibration method for secondary catheterization was improved,PICC was successfully inserted. The catheter tip was accurately placed in the distal third of the superior vena cava.The catheter was maintained for 6 months and removed after treatment without thrombosis aggravation,detachment,malposition or other complications.

Cite this article

XU Zhe , YU Chao , WU Xiaoli . Nursing cooperation in PICC catheterization for patients with bilateral internal jugular vein thrombosis using magnetic navigation combined with intracardiac electrocardiogram technology[J]. Chinese Journal of Emergency and Critical Care Nursing, 2026 , 7(9) : 1150 -1152 . DOI: 10.3761/j.issn.2096-7446.2026.09.020

References

[1] 封凤, 徐红霞, 王铃, 等. 44例PICC原发性上腔静脉内异位患者的护理[J]. 中华护理杂志, 2021, 56(6):904-906.
  Feng F, Xu HX, Wang L, et al. Nursing care of 44 patients with primary intracaval malposition of PICC in the superior vena cava[J]. Chin J Nurs, 2021, 56(6):904-906.
[2] Takakura M, Fujii T, Suzuki S, et al. Interference of a ventri-cular assist device with magnetic navigation during insertion of Sherlock 3CGTM,a bedside peripherally inserted central catheter[J]. J Artif Organs, 2022, 25(2):105-109.
[3] Uchida S, Takekawa D, Hori M, et al. Bedside insertion of a peripherally inserted central catheter into a patient with BMI of 84.8 kg/m2 using a magnetic tracking and electrocardio-gram-based tip confirmation system:a case report[J]. JA Clin Rep, 2022, 8(1):69.
[4] Chen YL, Chen H, Yang JQ, et al. Patterns and risk factors of peripherally inserted central venous catheter-related sympto-matic thrombosis events in patients with malignant tumors receiving chemotherapy[J]. J Vasc Surg Venous Lymphatic Di-sord, 2020, 8(6):919-929.
Outlines

/

〈 〉