ISSN 2097-6046(网络)
ISSN 2096-7446(印刷)
CN 10-1655/R
主管:中国科学技术协会
主办:中华护理学会
护理技术研究

双侧颈内静脉血栓患者PICC置管中行磁导航联合心腔内心电技术的护理配合

  • 胥喆 ,
  • 俞超 ,
  • 伍潇丽
展开
  • 1 浙江大学医学院附属第一医院静脉治疗护理门诊 杭州市 310003
    2 浙江大学医学院附属第一医院重症监护室 杭州市 310003
胥喆:女,硕士,主管护师,E-mail:206485@zju.edu.cn
作者贡献声明

胥喆:论文撰写、研究实施;俞超:研究指导;伍潇丽:研究实施

*俞超,E-mail:linxiaosu@zju.edu.cn

收稿日期: 2025-11-30

  网络出版日期: 2026-08-31

基金资助

浙江省医药卫生科技计划项目(2022KY771)

Nursing cooperation in PICC catheterization for patients with bilateral internal jugular vein thrombosis using magnetic navigation combined with intracardiac electrocardiogram technology

  • XU Zhe ,
  • YU Chao ,
  • WU Xiaoli
Expand
  • 1 Vascular Access Nurse Specialist Clinic, the First Affiliated Hospital Zhejiang University School of Medicine, Hangzhou 310003
    2 Intensive Care Unit, the First Affiliated Hospital Zhejiang University School of Medicine, Hangzhou 310003

Received date: 2025-11-30

  Online published: 2026-08-31

Supported by

Zhejiang Provincial Medical and Health Science and Technology Program Project(2022KY771)

摘要

针对1例双侧颈内静脉血栓患者,采用磁导航联合心腔内心电技术实时定位,配合体位、呼吸管理与导管动态调控,精准控制导管走向,并改良二次送管时校准方法,成功完成置管。最终导管尖端精准定位于上腔静脉下1/3段,患者导管留置6个月后因治疗结束拔管,未发生颈内血栓加剧或脱落、导管异位等置管相关并发症。

本文引用格式

胥喆 , 俞超 , 伍潇丽 . 双侧颈内静脉血栓患者PICC置管中行磁导航联合心腔内心电技术的护理配合[J]. 中华急危重症护理杂志, 2026 , 7(9) : 1150 -1152 . DOI: 10.3761/j.issn.2096-7446.2026.09.020

Abstract

For a patient with bilateral internal jugular vein thrombosis,magnetic navigation combined with intracavitary electrocardiography technology was used for real-time positioning,coupled with posture and respiratory management,as well as dynamic catheter adjustment,to precisely control the catheter trajectory. Additionally,a modified calibration method for secondary catheterization was improved,PICC was successfully inserted. The catheter tip was accurately placed in the distal third of the superior vena cava.The catheter was maintained for 6 months and removed after treatment without thrombosis aggravation,detachment,malposition or other complications.

参考文献

[1] 封凤, 徐红霞, 王铃, 等. 44例PICC原发性上腔静脉内异位患者的护理[J]. 中华护理杂志, 2021, 56(6):904-906.
  Feng F, Xu HX, Wang L, et al. Nursing care of 44 patients with primary intracaval malposition of PICC in the superior vena cava[J]. Chin J Nurs, 2021, 56(6):904-906.
[2] Takakura M, Fujii T, Suzuki S, et al. Interference of a ventri-cular assist device with magnetic navigation during insertion of Sherlock 3CGTM,a bedside peripherally inserted central catheter[J]. J Artif Organs, 2022, 25(2):105-109.
[3] Uchida S, Takekawa D, Hori M, et al. Bedside insertion of a peripherally inserted central catheter into a patient with BMI of 84.8 kg/m2 using a magnetic tracking and electrocardio-gram-based tip confirmation system:a case report[J]. JA Clin Rep, 2022, 8(1):69.
[4] Chen YL, Chen H, Yang JQ, et al. Patterns and risk factors of peripherally inserted central venous catheter-related sympto-matic thrombosis events in patients with malignant tumors receiving chemotherapy[J]. J Vasc Surg Venous Lymphatic Di-sord, 2020, 8(6):919-929.
文章导航

/

〈 〉